Download
2-Color Display Digital Pressure Switch For General Fluids ZSE80/ISE80 Series Details – Cảm Biến Áp Suất SMC

2-Color Display Digital Pressure Switch For General Fluids ZSE80/ISE80 Series product image
2-Color Display Digital Pressure Switch For General Fluids ZSE80/ISE80 Series Specifications
Model Number Notation

Model number notation: images
Made to order specifications
| Indicator symbol | Specifications/contents |
|---|---|
| X500 Note 1) | Wetted parts SUS316L |
| X501 | Lead wire length 3 m |
| X510 Note 2) | Restrictor installed fitting |
| X531 Note 3) | Compatible with M12 4-pin pre-wired connector |
| X555 Note 4) | Rated pressure range -100 to 300 kPa |
Note) Rear ported only
Note 1) Not compatible with rated pressure range -0.1 to 2 MPa specification.
Note 2) Piping specifications other than A2, B2
Note 3) Applicable only to output specifications A, B
Note 4) Applicable only to output specifications R, T
Option
| Options | Piping direction | Part number |
|---|---|---|
| Bracket | Rear ported | ZS-24-A |
| Rear ported | ZS-24-D | |
| Bottom ported | ZS-35-A | |
| Panel-mount adapter | Rear ported | ZS-35-C |
| Bottom ported | ZS-35-B | |
| Panel-mount adapter + Front protective cover | Rear ported | ZS-35-F |
| Bottom ported | ZS-35-E |
Specifications Table
| Model | ZSE80 (Vacuum pressure) | ZSE80F (Compound pressure) | ISE80 (Positive pressure) | ISE80H (Positive pressure) | ||
|---|---|---|---|---|---|---|
| Rated pressure range | 0.0 to -101.0 kPa | -100.0 to 100.0 kPa | -0.100 to 1.000 MPa | -0.100 to 2.00 MPa | ||
| Display / Set pressure range | 10.0 to -111.1 kPa | -110.0 to 110.0 kPa | -0.105 to 1.100 MPa | -0.105 to 2.20 MPa | ||
| Pressure resistance | 500 kPa | 2 MPa | 4 MPa | |||
| Wetted parts material | Pressure sensor: SUS630, Fittings: SUS304 (Gasket: NBRNote 1)) | |||||
| Applicable fluid | Liquid or gas that will not corrode SUS630 or SUS304 (NBRNote 1)) | |||||
| Piping connection port diameter | R1/4, NPT1/4, G1/4Note 2), URJ1/4, TSJ1/4, Rc1/8 Piping direction: Rear/bottom |
|||||
| Power supply voltage | 12 to 24 V DC ±10%, Ripple (p-p) 10% or less (with reverse connection protection) | |||||
| Current Consumption | 45 mA or less | |||||
| Switch output | – | NPN 1 output, NPN 2 outputs, PNP 1 output, PNP 2 outputs | ||||
| Max Load Current | 80 mA | |||||
| Maximum applied voltage | 28 V (at NPN output) | |||||
| Residual Voltage | 1 V or less (with load current of 80 mA) | |||||
| Response time | 2.5 ms (Response time selections with anti-chattering function: 20, 100, 500, 1,000, 2,000 ms can be selected) | |||||
| Short-circuit protection | Equipped | |||||
| Repeatability | ±0.2% F.S. ±1 digit | |||||
| Hysteresis | Hysteresis | Variable (0 or above) | ||||
| Window comparator | ||||||
| Analog Output | Voltage output | Output voltage (rated pressure range) |
1 to 5 V ±2.5% F.S. | 0.6 to 5 V ±2.5% F.S. | 0.8 to 5 V ±2.5% F.S. | |
| Linearity | ±1% F.S. | |||||
| Output impedance | Approx. 1 kΩ | |||||
| Current output | Output current (rated pressure range) |
4 to 20 mA ±2.5% F.S. | 2.4 to 20 mA ±2.5% F.S. | 3.2 to 20 mA ±2.5% F.S. | ||
| Linearity | ±1% F.S. | |||||
| Load impedance | Maximum load impedance: 300 Ω, (power supply voltage 12 V) Maximum load impedance: 600 Ω (power supply voltage 24 V) Minimum load impedance: 50 Ω |
|||||
| Auto-shift input | Non-voltage input (reed or solid state), Low level 0.4 V or less, input time 5 ms or more | |||||
| Display Method | 3 1/2 digit 7-segment LCD 2-color display (red/green) | |||||
| Display accuracy | ±2% F.S. ±1 digit (at ambient temperature of 25 ±3°C) | |||||
| Status LEDs | Lights up when switch output is turned ON, OUT1, OUT2: orange | |||||
| Functions | Anti-chattering, zero-clear, key lock, auto-shift, display unit switching, power-saving mode | |||||
| Environmental resistance | Enclosure | IP65 | ||||
| Operating temperature range | During operation: 0 to 50°C, During storage: -10 to 60°C (No condensation or freezing) | |||||
| Operating Humidity Range | When operating/stored: 35 to 85% RH (no condensation) | |||||
| Withstand Voltage | 250 V AC for 1 min between terminals and housing | |||||
| Insulation Resistance | 2 MΩ or more (50 V DC measured via megohmmeter) between terminals and housing | |||||
| Temperature characteristics | ±3% F.S. (25°C reference within operating temperature range) | |||||
| Lead wire | Oilproof vinyl heavy-duty cable, 3 cores (N.P.) ø3.5 (3.5‑mm diameter) 2 m Oilproof vinyl heavy-duty cable, 4 cores (A.B.) Conductor area: 0.15 mm2(AWG26) Oilproof vinyl heavy-duty cable, 5 cores (R.T.S.V.) Insulator O.D.: 0.95 mm |
|||||
| Standard | CE UL/CSA (E216656) | |||||
Note 1) When F02 (G1/4) is selected.
Note 2) F02 (G1/4) is available for rear ported only.
ISE80-02-B-B
ISE80-02-B-MD
ISE80-02-N
ISE80-02-N-M
ISE80-02L-A
ISE80-02L-N
ISE80-02L-N-M
ISE80-B2-R-M
ISE80-N02-T
ISE80H-02-N
ZS-35-A
ZSE80-C01-R-A-X501
ZSE80F-02L-N