Fluid | Air | ||||||
---|---|---|---|---|---|---|---|
Switching Method | N.C. or N.O. (Variable) | ||||||
Pilot Method | Internal Pilot Type | External pilot type | |||||
For general use | For vacuum and low pressures | For general use | |||||
Operating Pressure Range MPa | Main pressure | 0.2 to 0.8 | -101.2 kPa to +0.2 | 0.2 to 0.8 | |||
Pilot Pressure | 0.2 to 0.3 | – | |||||
Ambient Temperature and Operating Fluid Temperature °C | 0 (no freezing) to 60 | ||||||
*1: Response Time ms (at 0.5 MPa) | ON | AC | 30 or less | OFF | AC | 30 or less | |
DC | 40 or less | DC | 30 or less | ||||
Maximum Operating Frequency Hz | 3 | ||||||
*2: Lubrication | Required (turbine oil class1 ISO VG32 equivalent) | ||||||
Manual Operation | Yes (non-locking) | ||||||
Mounting Orientation | Free | ||||||
*3: Impact Resistance / Vibration Resistance: m/s2 | 150/50 |
*1: Based on JIS B 8419:2010 dynamic performance test. (Coil temperature of 20°C, at rated voltage, with no surge voltage suppressor).
*2: The solenoid valve is a lubrication type. Use an equivalent class 1 turbine oil (ISO VG32).
*3: Impact resistance: No malfunctions after testing using a drop-type impact tester under the following conditions: in the axial direction and at a right angle to the main valve and armature in both energized and non-energized states (once for each condition state). (Initial value)
Vibration resistance: No malfunctions occurred in a 1-sweep test between 45 and 1,000 Hz. The test was performed in both energized and non-energized states and in the axial direction and at right angles to the main valve and armature. (Initial value)
Solenoid Specifications
Electrical Entry | Standard | Grommet (G), conduit terminal (T), DIN terminal (D) | |
---|---|---|---|
Semi-standard | Conduit terminal with light (TL), Conduit terminal with surge voltage suppressor (TS), Conduit terminal with light / surge voltage suppressor (TZ), DIN terminal with light (DL), DIN terminal with surge voltage suppressor (DS), DIN terminal with light and surge voltage suppressor (DZ) |
||
Coil Rated Voltage | AC (50/60 Hz) | 100 V, 200 V, *110 V, *220 V, *240 V | |
DC | *12 V, 24 V | ||
Allowable Voltage Fluctuation | -15% to +10% of rated voltage | ||
*1: Apparent Power | AC | Starting | 73 VA (50 Hz), 58 VA (60 Hz) |
Holding | 28 VA (50 Hz), 17 VA (60 Hz) | ||
*Power Consumption | DC | 12W |
- *Semi-standard
*At rated voltage
VP3145-031DA1
VP3145-031DA1-X81
VP3145-031DA-Q
VP3145-031DB
VP3145-031DB1
VP3145-031DLA
VP3145-031DLA1
VP3145-031DLA-N
VP3145-031DLA-Q
VP3145-031DLB
VP3145-031DLB1
VP3145-031DZA
VP3145-031DZA1
VP3145-031DZA1-X80
VP3145-031DZA1-X81
VP3145-031DZA-Q
VP3145-031DZB
VP3145-031GA
VP3145-031GA1
VP3145-031GA1-X80
VP3165-061DA1
VP3165-061DA1-N-X81
VP3165-061DA1-X80
VP3165-061DA1-X81
VP3165-061DA-F
VP3165-061DA-Q
VP3165-061DB
VP3165-061DB1
VP3165-061DB1-X81
VP3165-061DLA
VP3165-061DLA1
VP3165-061DLA-Q
VP3165-061DLB
VP3165-061DLB1
VP3165-061DZA
VP3165-061DZA1
VP3165-061DZA1-X80
VP3165-061DZA1-X81
VP3165-061DZB
VP3165-061DZB1
VP3165-061DZB1-N
VP3165-061DZB1-X81
VP3185-121DA1
VP3185-121DB
VP3185-121DB1
VP3185-121DB1-X81
VP3185-121DLA
VP3185-121DLA1
VP3185-121DLB
VP3185-121DLB1
VP3185-121DZA
VP3185-121DZA1
VP3185-121DZA1-N
VP3185-121DZA1-N-X81
VP3185-121DZA1-X80
VP3185-121DZA1-X81
VP3185-121DZA-Q
VP3185-121DZB
VP3185-121DZB1
VP3185-121DZB1-X81
VP3185-121GA
VP3185-121GA1
VP3185-121GA1-X81
VP3185-121GB
VP3185-121GB1
VP3185-121GB1-X81
VT3113-001D-Q
VT3113-001DL
VT3113-001DL-Q
VT3113-001DS
VT3113-001DZ
VT3113-001TL
VT3113-002D
VT3113-002DL
VT3113-002TL
VT3113-002TZ
VT3113-003D-Q
VT3113-003DL
VT3113-003DL-Q
VT3113-003DZ
VT3113-003DZ-Q
VT3113-003T
VT3113-003TZ
VT3113-004D
VT3113-004D-Q
VT3113-004DL-Q
VT3113-004DZ
VT3113-004DZ-Q
VT3113-004TL
VT3113-004TZ
VT3113-005D-Q