Download
Compact Direct Operated 2/3 Port Solenoid Valve For Chemical Liquids LVM20/200 Series Specifications – Van điện từ khí nén SMC
Body ported type (tubing type) external appearance
Base Mounted Type (Without Sub-Plate) external appearance
Base Mounted Type (With Sub-Plate) external appearance
Model | Body Ported Type (Tubing Type) | Base Mounted Type | ||||||
---|---|---|---|---|---|---|---|---|
LVM20R1 | LVM20R2 | LVM202R | LVM20R3 | LVM20R4 | LVM205R | |||
Valve Structure | Diaphragm type direct acting poppet (rocker type) | |||||||
Valve Type | N.C. | N.O. | Universal | N.C. | N.O. | Universal | ||
Number of Ports | 2 | 3 | 2 | 3 | ||||
Fluids*1 | Air, water, deionized water (pure water), diluent, detergent | |||||||
Operating Pressure Range | -75 kPa to 0.25 MPa | -75 kPa to 0.3 MPa | ||||||
Orifice Diameter | 2 mm | |||||||
Response Time*8 | 20 ms or less (with pneumatic pressure) | |||||||
Leakage Rate | Zero for both internal and external parts (with hydraulic pressure) | |||||||
Proof Pressure*2 | 0.38 MPa | 0.45 MPa | ||||||
Ambient Operating Temperature*9 | 0 to 50°C | |||||||
Operating Fluid Temperature*9 | 0°C to 50°C (no freezing) | |||||||
Volume of Valve Chamber*3 | 84 μL | |||||||
Mounting Orientation*4 | Free | |||||||
Enclosure | IP40 equivalent | |||||||
Weight | 80 g | 80 g (without sub-plate), 94 g (with sub-plate) | ||||||
Rated Voltage | 12, 24 V DC | |||||||
Allowable Voltage Fluctuation*5 | ±10% of rated voltage | |||||||
Coil Insulation Type | Class B | |||||||
Power Consumption – Current (at 24‑V rated voltage) |
Standard Type | 2.5 W (0.1 A) |
||||||
With power-saving circuit | Inrush | 4 W (0.17 A) |
||||||
Holding | 0.6 W | |||||||
Coil Switching Noise*6 | 60 dB |
*1: Select an appropriate material for the wetted parts according to the type of fluid to be used. Be sure to check the chemical resistance beforehand.
*2: Indicates pressures which do not cause breakage or cracks after a 1 minute airtight test.
*3: Indicates the volume of the clearance inside the volume chamber after the volume of the diaphragm has been subtracted.
*4: As the body (orifice shape) is designed to eliminate residual liquid, mounting in a vertical orientation with the coil facing upward is recommended. If liquid pooling is not an issue, it may be installed in any orientation.
*5: If response speed is considered critical, take adequate regulations to prevent voltage fluctuations on the negative side.
*6: This value is depending on the measurement conditions and the sound level may change depending on the measurement conditions.
*7: See the SMC catalog if the valve is to be energized continuously for extended periods of time.
*8: According to JIS B8419:2010
{Value at an ambient and fluid temperature of 25°C, at rated voltage, at the maximum operating pressure (air) and when the N.C. (IN) port is pressurized}
The response time may vary depending on the supply pressure, fluid quality, piping conditions, ambient temperature, etc.
*9: Note that when the diaphragm material is Kalrez, the valve changeover time becomes significantly longer at ambient and fluid temperatures of 15°C or less in comparison to at room temperature (roughly 25°C).
- *Kalrez is a registered trademark of E. I. du Pont de Nemours and Company or its affiliates.
Flow Rate Characteristics
- Water: Kv 0.055 / Cv 0.065
- Air: C 0.23 / b 0.27
*Kv, Cv values conform to JIS B 2005:1995. C and b values conform to JIB B8390:2000.
LVM202R-5A-10
LVM202R-5A-Q
LVM202R-5B
LVM202R-5C
LVM202R-6A
LVM202R-6B-Q
LVM202R-6C
LVM202RY-5A
LVM202RY-5A-Q
LVM202RY-5B
LVM202RY-6A
LVM202RY-6B
LVM202RY-6B-Q
LVM205R-5A
LVM205R-5A1
LVM205R-5A1F
LVM205R-5A1N-Q
LVM205R-5A-6
LVM205R-5A-10-Q
LVM205R-5A-Q
LVM205R-5B
LVM20R1-5A-6
LVM20R1-5A-Q
LVM20R1-5B
LVM20R1-5C
LVM20R1-5C-Q
LVM20R1-6A
LVM20R1-6B
LVM20R1-6C
LVM20R1Y-5A
LVM20R1Y-5B
LVM20R1Y-5C-10
LVM20R1Y-6A
LVM20R1Y-6B
LVM20R1Y-6B-Q
LVM20R2-5A
LVM20R2-5B
LVM20R2Y-6A
LVM20R3-5A
LVM20R3-5A1
LVM20R3-5A1-6
LVM20R3-5A1-6-Q
LVM20R3-5A1-10
LVM20R3-5A1N-6
LVM20R3-5A-6
LVM20R3-5A-10-Q
LVM20R3-5B
LVM20R3-5B1
LVM20R3-5B1-6
LVM20R3-5B1-10
LVM20R3-5B-6
LVM20R3-5B-10
LVM20R3-5C
LVM20R3-5C1
LVM20R3-5C1-6
LVM20R3-5C1-10
LVM20R3-5C1-10-Q
LVM20R4-5A
LVM20R4-5A1
LVM20R4-5B
LVM20R4-5B1
LVM20R4-5B1N
LVM20R4-5C1
LVM20R4-6A
LVM20R4-6B
LVM20R4-6B1
LVM20R4-6C
LVM20R4-6C1N-6
LVM20R4Y-5A