Download
ARM11B Series Individual Supply Type Manifold Regulator Detailed Example
ARM11B Series Individual Supply Type Manifold Regulator product image
ARM11B Series Individual Supply Type Manifold Regulator Specifications
Model Number Notation
Model number example
(1) Knob Position
Knob position
Symbol | Position |
---|---|
A | Top |
B | Front |
C | Bottom |
(2) IN/OUT Piping Position
IN/OUT piping position
Symbol | Position | |||
---|---|---|---|---|
IN Side | OUT Side | |||
Bottom | Top | Bottom | Top | |
1 | ● | – | ● | – |
2 | – | ● | – | ● |
3 | ● | – | – | ● |
4 | – | ● | ● | – |
(3) Regulator Block Stations
Symbol | Number of stations |
---|---|
1 | 1 station |
2 | Double |
3 | Triple |
4 | 4 stations |
5 | 5 stations |
6 | 6 stations |
7 | 7 stations |
8 | 8 stations |
9 | 9 stations |
M | 10 stations |
(4) IN/OUT Fitting Type
IN/OUT fitting type
(Unit: mm)
Mounting position | IN side | OUT side | ||||||
---|---|---|---|---|---|---|---|---|
Symbol | Fitting Type | |||||||
Straight | Elbow Note) | Straight | Elbow Note) | |||||
ø4 (diameter 4 mm) | ø6 (diameter 6 mm) | ø4 (diameter 4 mm) | ø6 (diameter 6 mm) | ø4 (diameter 4 mm) | ø6 (diameter 6 mm) | ø4 (diameter 4 mm) | ø6 (diameter 6 mm) | |
06 | ● | – | – | – | ● | – | – | – |
07 | – | ● | – | – | ● | – | – | – |
08 | – | ● | – | – | – | ● | – | – |
18 | – | – | ● | – | – | – | ● | – |
19 | – | – | – | ● | – | – | ● | – |
20 | – | – | – | ● | – | – | – | ● |
25 | ● | – | – | – | – | – | ● | – |
26 | – | ● | – | – | – | – | ● | – |
27 | – | ● | – | – | – | – | – | ● |
32 | – | – | ● | – | ● | – | – | – |
33 | – | – | – | ● | ● | – | – | – |
34 | – | – | – | ● | – | ● | – | – |
(unit: inches)
Mounting position | IN side | OUT side | ||||||
---|---|---|---|---|---|---|---|---|
Symbol | Fitting Type | |||||||
Straight | Elbow Note) | Straight | Elbow Note) | |||||
ø5/32 (Diameter 5/32 mm) | ø1/4 (diameter 1/4 mm) | ø5/32 (Diameter 5/32 mm) | ø1/4 (diameter 1/4 mm) | ø5/32 (Diameter 5/32 mm) | ø1/4 (diameter 1/4 mm) | ø5/32 (diameter 15/32 mm) | ø1/4 (diameter 1/4 mm) | |
56 | ● | – | – | – | ● | – | – | – |
57 | – | ● | – | – | ● | – | – | – |
58 | – | ● | – | – | – | ● | – | – |
68 | – | – | ● | – | – | – | ● | – |
69 | – | – | – | ● | – | – | ● | – |
70 | – | – | – | ● | – | – | – | ● |
75 | ● | – | – | – | – | – | ● | – |
76 | – | ● | – | – | – | – | ● | – |
77 | – | ● | – | – | – | – | – | ● |
82 | – | – | ● | – | ● | – | – | – |
83 | – | – | – | ● | ● | – | – | – |
84 | – | – | – | ● | – | ● | – | – |
- *Note) When the knob and the OUT piping positions are on the same side, the elbow fitting is directed to the rear side (DIN rail side). For types with a digital pressure switch, depending on the piping direction, be sure to apply caution so as to ensure that there is no interference with the connector.
(5) Accessories (Pressure Display)
Accessories (pressure display)
Symbol | Accessory |
---|---|
Nil | Without pressure display |
ANote 1) | With pressure display |
- *Note 1) “Pressure display” means that the product comes with a pressure gauge or a digital pressure switch. For types with a digital pressure switch, select a symbol from (8) Digital Pressure Switch Output Specifications. If a symbol from (8) Digital Pressure Switch Output Specifications is not selected, then a pressure gauge will be included with the regulator.
- *Note 2) Pressure gauges are not compatible with copper/fluorine-free specifications.
(6) Semi-standard Specifications
Symbol | None | 0.35 MPa settingNote 1) | Non-relieving | Oil-freeNote 2) |
---|---|---|---|---|
Nil | ● | – | – | – |
1 | – | ● | – | – |
2 | – | – | ● | – |
3 | – | – | – | ● |
4 | – | ● | ● | – |
5 | – | ● | – | ● |
6 | – | – | ● | ● |
7 | – | ● | ● | ● |
- *Note 1) A pressure gauge with a full span of 0.4 MPa is attached.
- *Note 2) The oil-free specification is grease-free in the fluid-contacting areas.
(7) Unit Representation
Symbol | Description |
---|---|
Nil | Unit used on product nameplate and pressure gauge is MPa |
ZNote 1, 2) | Unit used on product nameplate and pressure gauge is psi |
ZANote 1, 3) | Digital pressure switch: with unit switching (initial setting is MPa) |
- *Note 1) Under new Japanese measurement laws, this product is only available for sale outside of Japan (SI units are used in Japan).
- *Note 2) The digital pressure switch is equipped with unit switching and has a default setting of psi.
- *Note 3) This option is available with the digital pressure switch. Includes lead wire with connector (2 m).
(8) Digital Pressure Switch Output Specifications
Symbol | Content |
---|---|
Nil | None |
N | NPN open collector |
P | PNP open collector |
- *Note) For types with a digital pressure switch, the pressure display as outlined in (5) Accessories is required. The electrical entry of the lead wire is positioned on the opposite side to the knob.
Specifications
Regulator Construction | Direct Acting | |
---|---|---|
Working Principle | Diaphragm Regulator | |
Relief Mechanism | Standard | Relieving Type |
Semi-standard | Non-relieving Type | |
Backflow Function Note 1) | Yes (unbalanced type) | |
IN Side Tubing Outer Diameter | ø4 (diameter 4 mm), ø6 (diameter 6 mm), ø5/32 (diameter 5/32 mm), ø1/4 (diameter 1/4 mm) | |
OUT Side Tubing Outer Diameter | ø4 (diameter 4 mm), ø6 (diameter 6 mm), ø5/32 (diameter 5/32 mm), ø1/4 (diameter 1/4 mm) | |
Proof pressure | 1.5 MPa | |
Maximum operating pressure | 1.0 MPa | |
Set pressure range | Standard | 0.05 to 0.7 MPa |
Semi-standard | 0.05 to 0.35 MPa (low-pressure type) | |
Applicable fluids | Air | |
Ambient and operating fluid temperature Note 2) | 5 to 60°C |
- *Note 1) When using the backflow function, a set pressure of at least 0.1 MPa is required.
- *Note 2) For the type with a digital pressure switch: 5 to 50°C.
Diagram
ARM11B Series Individual Supply Type Manifold Regulator diagram
Component parts
Number | Part name | Material |
---|---|---|
1 | Body for regulator block | PBT |
2 | Bonnet | PBT |
3 | Knob | POM |
4 | Valve seat | POM |
5 | Adjusting screw assembly | Steel for construction |
6 | Adjustment spring | Steel wire |
7 | Regulator clip | Stainless steel |
8 | Manifold block | PBT |
9 | Blanking plate assembly | – |
10 | Square nut | Steel strip |
11 | Individual supply bushing | POM |
Replacement parts
Number | Part name | Material | Part number | Application |
---|---|---|---|---|
A | Diaphragm assembly | Weatherproof NBR/POM | 136126A | Relieving Type |
136126-1A | Non-Relieving Type | |||
B | Valve | HNBR, aluminum alloy | 136127-30#1 | – |
C | Valve spring | Stainless steel | 136131 | – |
D | Gasket | HNBR | 136137-30 | – |
E | O-ring | NBR | 136146 | Standard model |
HNBR | 136146-30 | Oil-free specification | ||
F | O-ring | NBR | 136147 | Standard product |
HNBR | 136147-30 | Oil-free specification | ||
G | O-ring | NBR | 136148 | Standard product |
HNBR | 136148-30 | Oil-free specification | ||
NBR | KA01731 | Standard model for digital pressure switch | ||
HNBR | KA01613 | Oil-free spec. for digital pressure switch | ||
H | O-ring | NBR | 136149 | Standard product |
HNBR | 136149-30 | Oil-free specification | ||
J | Fitting assembly | – | – | – |
K | Port plug | PBT, HNBR | – | – |
ARM11B Series Individual Supply Type Manifold Regulator Dimensions Example
(Unit: mm)
ARM11BA1-□08 knob position, top, dimensional drawing
No. of stations | DIN Rail Part No. | L2 Dimension |
---|---|---|
1 | AXT100-DR-8 | 110.5 |
2 | AXT100-DR-10 | 135.5 |
3 | AXT100-DR-12 | 160.5 |
4 | AXT100-DR-14 | 185.5 |
5 | AXT100-DR-16 | 210.5 |
6 | AXT100-DR-19 | 248 |
7 | AXT100-DR-21 | 273 |
8 | AXT100-DR-23 | 298 |
9 | AXT100-DR-25 | 323 |
M | AXT100-DR-28 | 360.5 |
Basic Information
Applicable Fluid | Air | Shape | One-Touch Coupling Type |
---|